Language selection

Kosmonavtov Pr., h. 6э

Altai Region, Barnaul

Barnaul
Boiler Plant

5с-1-2 Float-Type Steam Traps

Buy
Download description

Production according to TR 3740-002-15365247-2004 

Pipeline connection: using a pipe with a gradient of 1:10 to the side of the steam trap.
Installation position on the pipeline: with the cover upwards.
The steam traps are designed for installation in closed premises.
Gate sealability: according to class А GOST 9544-2015.
Climatic version: У, УХЛ, Т according to GOST 15150-69.
Placement category: 3 according to GOST 15150-69.

DN, mm PN, MPa Tmax of the Medium, ºC Body Material, Steel Working Medium Max. Pressure Differential, MPa Weight without Electric Actuator, kg
25 10 450 20 Пароводяная смесь 0,25 52
DN - Nominal Diameter
PN - Nominal Pressure
P - Pressure
Tmax - Maximum Design Temperature 
Mкр - Spindle Torque
t - Response time
μ - Fluid Flow Coefficient
h - Valve Stroke
Kv - Throughput Capability
F - Seat Area
ζ - Resistance Coefficient

The opening or closing of the blocking element of the steam trap is carried out automatically with the help of a float thanks to the difference in densities of the water steam and condensate (2nd group fluid and its vapors).

According to GOST 356-80, the items designed for the ultimate pressure allow their application on operating parameters within the following range:
from 10 MPa, 200 °С to 3,6 MPa, 455 °С.

The below table demonstrates technical specifications of the steam traps manufactured by BKZ, LLC.

Your product added to order!
Continue watching
Go to order

Сайт использует файлы Cookie, продолжая вы даете свое согласие на обработку своих персональных данных