Language selection

Kosmonavtov Pr., h. 6э

Altai Region, Barnaul

Barnaul
Boiler Plant

5с-1-2 Float-Type Steam Traps

Buy
Download description

Production according to TR 3740-002-15365247-2004 

Pipeline connection: using a pipe with a gradient of 1:10 to the side of the steam trap.
Installation position on the pipeline: with the cover upwards.
The steam traps are designed for installation in closed premises.
Gate sealability: according to class А GOST 9544-2015.
Climatic version: У, УХЛ, Т according to GOST 15150-69.
Placement category: 3 according to GOST 15150-69.

DN, mm PN, MPa Tmax of the Medium, ºC Body Material, Steel Working Medium Max. Pressure Differential, MPa Weight without Electric Actuator, kg
25 10 450 20 Пароводяная смесь 0,25 52
DN - Nominal Diameter
PN - Nominal Pressure
P - Pressure
Tmax - Maximum Design Temperature 
Mкр - Spindle Torque
t - Response time
μ - Fluid Flow Coefficient
h - Valve Stroke
Kv - Throughput Capability
F - Seat Area
ζ - Resistance Coefficient

The opening or closing of the blocking element of the steam trap is carried out automatically with the help of a float thanks to the difference in densities of the water steam and condensate (2nd group fluid and its vapors).

According to GOST 356-80, the items designed for the ultimate pressure allow their application on operating parameters within the following range:
from 10 MPa, 200 °С to 3,6 MPa, 455 °С.

The below table demonstrates technical specifications of the steam traps manufactured by BKZ, LLC.

Your product added to order!
Continue watching
Go to order