1085-100-ЭЧ
BuyProduction according to TR 3740-002-15365247-2004
Installation position: on horizontal and vertical pipeline sections with the medium
direction from the top downward.
Pipeline connection: welded connection.
Climatic version: У, УХЛ, ХЛ, Т according to GOST 15150-69.
Placement category: 2, 3 according to GOST 15150-69.
The valve control is carried out with the help of multi-turn built-in electric
actuators with a current position sensor.
D1, mm: | 146 |
D, mm: | 112 |
h, mm: | 1575 |
H, mm: | 1700 |
L, mm: | 400 |
DN, mm | Рр, MPa | Tmax of the Medium, ºC | Body Material, Steel | Working Medium | Operating Stroke, mm | F, cm² | TQ, N•m, maximum torque at spindle plug | Designation of the electric drive | N, kW | t хода, с. | Weight without Electric Actuator, kg | Full Weight, kg |
100 | 9,8 | 540 | 15Х1М1Ф | Пар | 10 | 24,0 | 153 | ПЭМ-Б2У | 0,55 | 24 | 163 | 203 |
DN - Nominal Diameter PN - Nominal Pressure P - Pressure |
Tmax - Maximum Design Temperature Mкр - Spindle Torque t - Response time μ - Fluid Flow Coefficient |
h - Valve Stroke Kv - Throughput Capability F - Seat Area ζ - Resistance Coefficient |
The slide control valves are used at heat power engineering sites for the control of the working medium flow or pressure.
The control is performed by means of changing the passage area, which is achieved through translational movement of the slide gate.
The maximum pressure differential on the valve is limited.