1438-20-Э-05
BuyProduction according to TR 2913-001-15365247-2004
Installation place: as a rule, the valves are installed on the cooling water injection
pipelines in DS, PRDS, FRPRDS and industrial pipelines.
Installation requirements: the valves are designed for outdoor installation and in
closed premises with the ambient temperature up to +70 С.
The valves equipped with built-in actuators shall be only installed on horizontal
pipeline sections with the actuator position upwards.
Pipeline connection: welded connection.
Climatic version: У, УХЛ, ХЛ, Т according to GOST 15150-69.
Placement category: 1, 2, 3 according to GOST 15150-69.
Depending on the lifting height of the valve needle, the throughput capability is
shown in the diagrams.
D1, mm: | 45 |
H, mm: | 905 |
h, mm: | 115 |
D, mm: | 32 |
d1, mm: | 28 |
d, mm: | 20 |
DN, mm | Рр, MPa | Tmax of the Medium, ºC | Body Material, Steel | Working Medium | Operating Stroke, mm | Max. Kv, m³/h | Max. Pressure Differential, MPa | F, cm² | TQ, N•m, maximum torque at spindle plug | Designation of the electric drive | N, kW | t хода, с. | h1, mm | Weight without Electric Actuator, kg | Full Weight, kg |
20 | 37,3 | 280 | 20 | Вода | 29 | 0,8 | 4 | 0,17 | 20кН* | МЭП-25000/100-50-У-99 | 0,3 | 58 | 70 | 13 | 38 |
DN - Nominal Diameter PN - Nominal Pressure P - Pressure |
Tmax - Maximum Design Temperature Mкр - Spindle Torque t - Response time μ - Fluid Flow Coefficient |
h - Valve Stroke Kv - Throughput Capability F - Seat Area ζ - Resistance Coefficient |
The control needle valves are used as fluid flow regulators.
The provision of smooth control within the limits of the rated throughput capability is achieved with the help of the valve needle form. The seat has reinforced hard-facing of increased hardness which is resistant erosive and corrosive wear.
They are not used as shutoff devices.
According to the actuator type of the working body and control method, the
control needle valves are divided into the following types:
- Lever-operated control needle valves. The valve control is carried out on a
remote basis (automatically) with actuators of single-turn electric actuator type
(МЭО) through the lever. The allowed pressure differential on the valve shall not
exceed 1 MPa. - Control needle valves. The valve control is carried out with a handwheel or an
actuator with a current position sensor of electric multi-turn actuator types
(ПЭМ) (ABS ZEIM Automation), SAR (AUMA) or linear pneumatic actuators
FESTO, VALBIA, AIR Torque, ROTORK etc., chosen considering the working
medium pressure and air pressure. The valves equipped with actuators shall be
only installed on horizontal pipeline sections with the actuator position
upwards. - Control angle valves. The valves are controlled with a built-in multi-turn electric
actuator with a current position sensor of electric multi-turn actuator / electric
multi-turn mechanism types (ПЭМ/МЭМ) (ABS ZEIM Automation), SAR (AUMA)
etc. or linear pneumatic actuators of electric multi-turn actuator types (МЭП)
(ABS ZEIM Automation), REGADA etc., chosen considering the working medium
pressure.
According to GOST 356-80, the valves designed for the ultimate pressure allow
their application on operating parameters within the following range:
— at PN 100 MPa – from 10 MPa, 200 °С to 3,6 MPa, 455 °С;
— at PN 63 MPa – from 6,3 MPa, 200 °С to 2,3 MPa, 455 °С;
— at PN 25 MPa – from 25 MPa, 200 °С to 9 MPa, 455 °С.